Please use this identifier to cite or link to this item:
https://cris.library.msu.ac.zw//handle/11408/1825
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Mashandudze, W. | - |
dc.contributor.author | Mufute, N.L. | - |
dc.contributor.author | Masaka, J. | - |
dc.date.accessioned | 2016-10-04T08:05:19Z | - |
dc.date.available | 2016-10-04T08:05:19Z | - |
dc.date.issued | 2015 | - |
dc.identifier.uri | http://hdl.handle.net/11408/1825 | - |
dc.description.abstract | Determination of emitter discharge variation and water application uniformity is very important in designing drip irrigation system and could serve as the basis for optimizing water use efficiency and crop productivity. This study was carried out at Eureka Farm in Sanyati District Zimbabwe, to evaluate the performance of one hectare gravityfed drip irrigation system under varying vertical pressure heads. The drip system was tested for emitter discharge variation (Q var), coefficient of uniformity (CU) and distribution uniformity (DU). The drip kit comprised of a 10 m3 tank, on an adjustable stand, with one hundred and twenty sets of 100 m long 16 mm diameter drip lines which had the same types of emitters. The operating heads tested were 2 m, 3 m, and 4 m. Emitter discharge was measured at the drip line lengths 12.5 m, 25 m, 37.5 m, 50 m, 62.5 m, 75 m, 87.5 m and 100 m from the manifold. The performances were compared to The American Society of Agricultural Engineers (ASAE) Standards (1999) and used to select the optimum drip lateral lengths for different vertical pressure head. The results indicated as expected that the emitter discharge decreased as the lateral length increased. The emitter discharge variation was within the desirable recommended standard of d” 10% at 100m, 75m and 65m drip lateral lengths for 4m, 3m and 2m tank heights respectively. The results also showed that the coefficient of uniformity (CU) and the distribution uniformity (DU) generally increase with increasing heads and decrease with increasing drip lateral length. The minimum recommended standards for DU and CU for the kit to be considered as good was 80% and 85% respectively. On the basis of the results, appropriate recommendations on the relationship between vertical head and drip lateral length were formulated to minimize non uniformity of water distribution under field conditions. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Midlands State University | en_US |
dc.relation.ispartofseries | Midlands State University Journal of Science, Agriculture and Technology;Special edition; p. 93-111 | - |
dc.subject | Drip kit, Vertical head, Drip lateral length, Emitter discharge variation ( ), Coefficient of uniformity (CU) and Distribution uniformity (DU). | en_US |
dc.title | A performance evaluation of a one hectare gravity fed drip irrigation system under varying vertical head | en_US |
dc.type | Article | en_US |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | open | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
Appears in Collections: | Research Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
MSUJSAT.pdf | Full Text | 9.13 MB | Adobe PDF | View/Open |
Page view(s)
80
checked on Nov 22, 2024
Download(s)
74
checked on Nov 22, 2024
Google ScholarTM
Check
Items in MSUIR are protected by copyright, with all rights reserved, unless otherwise indicated.